Opens in a new tab
Free standard shipping on eligible US orders $500+

McMiller RE-5C Copper Sulfate Reference Electrode for Cathodic Protection

SKU: RE-5C
Weight 2 lbs
Dimensions 8 × 8 × 8 in
Condition

New

Manufacturer Part Number

RE-5C

Brand

McMiller

$155.54

In stock — available to order.

Sold individually. Each quantity ordered is one unit. Kits are one complete kit; products sold by length use the stated length unit.

Same-item volume pricing
QuantityUnit priceSaving
1–4$155.540%
5–9$147.765%
10+$139.9910%

Estimate for this quantity before shipping. Tax display follows store settings. Existing cart quantities can increase the tier. Only one offer applies; a coupon replaces automatic pricing. For 20+ units, contact support for a quote.

Available to order.

Bulk quantity & quote

Enter the total quantity you need. We will confirm availability and a quote before you order.

Request this quantity →

Need a firm ship date? Availability may include supplier stock. Confirm availability before ordering for time-sensitive work.

Processing times & shipping information

The McMiller RE-5C Copper Sulfate Reference Electrode is a rugged, field-proven device used for cathodic protection testing and corrosion monitoring. Designed for pipelines, storage tanks, utility systems, and industrial plants, this electrode provides a stable and reliable reference potential for accurate electrochemical measurements.

Key Features:

  • Replacement copper sulfate reference electrode
  • Ensures stable, repeatable voltage readings
  • Rugged construction for field or laboratory use
  • Compatible with pipeline, tank, and utility corrosion testing systems
  • Manufactured by McMiller, a trusted leader in cathodic protection equipment

Applications:

  • Cathodic Protection Systems
  • Pipeline Monitoring
  • Storage Tank Corrosion Testing
  • Industrial Plant Corrosion Control
  • Utility Infrastructure Testing

Specifications:

Brand: McMiller
Part Number (MFG#): RE-5C
Type: Copper Sulfate Reference Electrode
Condition: Brand New

This RE-5C electrode is an essential replacement for technicians and engineers conducting pipeline, tank, and industrial cathodic protection testing, ensuring reliable long-term performance.

Important Notice – Propane Parts, Accessories, and Regulators

This product, including but not limited to propane parts, accessories, fittings, hoses, valves, and regulators, must be installed and serviced by a licensed professional in accordance with all applicable local, state, and federal codes, regulations, and standards.

The seller assumes no responsibility for the installation, inspection, application, maintenance, or use of this product.

It is the sole responsibility of the buyer to ensure the product is appropriate for their intended application and that it is installed correctly by a qualified individual.

Improper installation, maintenance, or use of propane products may result in serious injury, death, fire, explosion, or property damage.

The buyer accepts all risks, liabilities, and potential consequences associated with the use of this product.

By purchasing this item, the buyer acknowledges that they have read, understood, and agreed to these terms and confirm that installation and use will be conducted by a properly licensed and qualified professional.


Product Specifications

Specification Details
Brand M.C. Miller
Model RE-5C
Item Number 15210
Type Portable Reference Electrode
Electrode Type Copper/Copper Sulfate (Cu/CuSO₄)
Application Cathodic Protection / Corrosion Testing
Tip Conical ceramic plug
Internal Electrode High-purity copper rod
Body Rugged Lexan tube
Length 6.75 in. (17.15 cm)
Diameter 1.375 in. (3.49 cm)
Dry Weight 5 oz. (141.7 g)
Connector Male 1/4"-20 threaded end with thumb nut
Recommended Surface Soft soil

These dimensions and specifications come directly from M.C. Miller's current product listing. 

Product Description

The M.C. Miller RE-5C is a portable copper/copper sulfate (Cu/CuSO₄) reference electrode designed for cathodic-protection testing and corrosion-control measurements.

Unlike the standard RE-5's flat contact surface, the RE-5C uses a rugged conical ceramic plug specifically designed for soft-soil conditions. The pointed configuration can be pushed into soft soil and helps provide effective contact for field potential measurements. 

The electrode incorporates a high-purity copper rod inside a durable Lexan tube. A transparent viewing window allows the technician to inspect the condition of the saturated copper sulfate solution. The standard RE-5C is supplied dry with a charge of copper sulfate crystals; the user prepares the saturated solution according to the manufacturer's instructions. 

Key Features

  • Genuine M.C. Miller RE-5C
  • Copper/copper sulfate reference electrode
  • Conical ceramic contact plug
  • Specifically designed for soft-soil applications
  • High-purity copper electrode rod
  • Rugged Lexan body
  • Transparent solution inspection window
  • Supplied with copper sulfate crystals on the standard Item #15210 version
  • User-prepared saturated CuSO₄ solution
  • 1/4"-20 male threaded electrical connection
  • Thumb nut included on the standard configuration
  • Portable and reusable
  • Designed for field corrosion and cathodic-protection measurements 

Typical Applications

The RE-5C is commonly used for pipe-to-soil potential measurements and cathodic-protection surveys. It can also support specialized corrosion surveys such as CIPS and DCVG when used with the appropriate test equipment. 

Typical users include pipeline technicians, corrosion engineers, utilities, tank operators, cathodic-protection contractors, and infrastructure maintenance personnel.

RE-5C vs. RE-5

The main distinction is the ceramic contact tip. The RE-5C has a conical ceramic plug for soft soil, whereas the standard RE-5 uses a flat ceramic surface for more general soil-surface measurements. 

Brand: M.C. Miller
Model: RE-5C
MPN / Item Number: 15210
Product Type: Reference Electrode
Electrode Chemistry: Copper/Copper Sulfate (Cu/CuSO₄)
Tip Type: Conical Ceramic
Application: Cathodic Protection
Body Material: Lexan
Connector: Male 1/4"-20 with Thumb Nut
Length: 6.75"
Diameter: 1.375"
Dry Weight: 5 oz.
Measurement Application: Pipe-to-Soil / Corrosion Potential

Match the manufacturer part number and equipment model to the listing. Check connection sizes, fuel type, pressure or capacity, voltage and dimensions where applicable. A similar appearance or part number alone does not confirm compatibility.

For help, send a parts inquiry with the part number, equipment model, label photos and quantity. Manufacturer documents and item-specific information, when supplied, are in the product details above.

Availability may include our inventory and supplier sources. Listed stock does not by itself confirm immediate dispatch. Ask us to confirm a ship date before ordering for time-sensitive work.

Shipping methods and charges appear at checkout where available. Freight, oversized and specially handled items may require a quote. See our Shipping Policy for processing periods, restrictions and delivery information.

Explore related products

More products in this category. Compare specifications and fit for your application.