Specification Details
Brand Generant
MPN / Model VRVD-1000B-V-000.5-X
Series VRVD
Product Type Vent Relief / Pressure Relief Valve
Valve Type Direct-Acting Relief Valve
Configuration Vent to Atmosphere
Deflector Cap Yes
Port Size 1″ NPT
Body Material Brass
Seal Material Viton
Factory Set Pressure 0.5 PSIG
Series Pressure Range 0.5–150 PSIG
Set-Pressure Tolerance at <2 PSI ±10%
Nominal Reseat 50% of set pressure for 0.5–1.9 PSIG valves
Viton Temperature Range -10°F to 375°F (-23°C to 190°C)
Adjustment Internal / Tamper Resistant
Testing Factory Preset & Tested
Oxygen Service O2 Cleaned
Country/Region of Manufacture United States
Condition Specify New / New Old Stock / Used as applicable

Generant’s ordering literature confirms that VRVD designates a vent-to-atmosphere valve with deflector cap, 1000 identifies the 1″ NPT size, B denotes brass construction, and V denotes Viton sealing. The manufacturer’s specified Viton temperature range is -10°F to 375°F.  

GENERANT VRVD-1000B-V-000.5-X 1″ Brass Vent Relief Valve – Viton Seal – 0.5 PSIG – Deflector Cap – O2 Cleaned

Offered for sale is a Generant VRVD-1000B-V-000.5-X Vent Relief Valve, a compact, high-accuracy, direct-acting pressure relief valve designed for controlled venting of system pressure to atmosphere.

This VRVD configuration features a 1-inch NPT brass valve body, Viton sealing element, and a factory-set cracking pressure of 0.5 PSIG. It is equipped with a deflector cap, which helps direct discharged gas away from the valve while also providing the enhanced discharge characteristics associated with Generant’s VRVD design.

The valve uses Generant’s internally adjusted design to help prevent inadvertent changes to the factory pressure setting. Its Quad-ring sealing arrangement provides accurate and repeatable cracking performance with a narrow reseat band.

This particular valve is also specified as O2 cleaned, making it suitable for properly engineered oxygen-service systems where compatible materials, installation practices, and applicable safety requirements are observed.

KEY FEATURES

• Genuine Generant industrial relief valve
• Model / MPN: VRVD-1000B-V-000.5-X
• VRVD Series – Vent to Atmosphere with Deflector Cap
• 1″ NPT connection
• Durable brass construction
• Viton seal
• Factory set at 0.5 PSIG
• Direct-acting pressure relief design
• Accurate and repeatable cracking pressure
• Factory preset and tested
• Internal tamper-resistant pressure adjustment
• Excellent reseat characteristics
• Compact industrial design
• Deflector cap directs discharged gas away from valve
• O2 cleaned for oxygen-service applications
• Designed for dependable low-pressure relief and venting

APPLICATIONS

This valve is well suited for appropriately engineered:

• Industrial gas systems
• Oxygen-service equipment
• Gas distribution and handling systems
• Low-pressure gas manifolds
• Pressure protection systems
• Process gas equipment
• Gas storage and transfer systems
• Industrial and medical gas equipment
• Laboratory and specialty gas installations
• Pressure-controlled vessels and piping systems
• OEM gas-handling equipment

OPERATION

Under normal system pressure, the relief valve remains closed. When inlet pressure reaches the approximately 0.5 PSIG factory-set cracking pressure, the direct-acting mechanism begins opening to discharge excess pressure to atmosphere. As pressure decreases, the valve reseats automatically.

For Generant VRV/VRVD valves set between 0.5 and 1.9 PSIG, the manufacturer specifies nominal reseating at approximately 50% of set pressure.

IMPORTANT

Correct relief-valve sizing and selection depend on the complete system design, required relieving capacity, operating medium, temperature, pressure, materials compatibility, installation arrangement, and applicable codes. Buyers should verify that this exact model and set pressure are appropriate for their equipment before installation, particularly for oxygen service.

Product details

Part / SKU VRVD-1000B-V-000.5-X

Package includes

  • GENERANT VRVD-1000B-V-000.5-X 1" Brass Vent Relief Valve Viton 0.5 PSI O2 Clean

Included components and any stated pack quantity are as described in this listing. Optional accessories shown separately are sold separately unless expressly included above.

Explore related products

More products in this category. Compare specifications and fit for your application.